T2 series, one card and two-zone design, greatly saves the space occupied by the temperature control box. The LCD screen displays one screen to display all the parameter information of the heating zone. The two zones operate independently, and there is no need to switch between zones 1 and 2. The menu, full Chinese menu and all Chinese (or English) display alarm information is intuitive and easy to grasp.
Technical Parameters
Power Input:110~220V,50/60Hz
Power output: 16A3600W (7000W optional)
Temperature measurement: type / K type thermocouple temperature measurement, temperature range 50 ~ 500 degrees Celsius, accuracy 05%
Control method: fuzzy algorithm control
Features
Automatic Control
Manual Control
Soft Start Control
Alarm Function
Warm-line open alarm
Temperature sensing line reverse alarm
Ultra high temperature alarm and ultra low temperature alarm
Heater disconnect alarm
Thyristor damage alarm
T2 SeriesFeature Protection
380V zero line fire line misconnection protection
The heating line is wrongly connected to the temperature sensing line position alarm function (optional)
Tel:13812932603丨E-mai:yong.chen@maivismold.com丨Address: Room 3, No. 36 Dongchang Road, Bacheng Town, Kunshan City Copyright ? Mavis Molding Technology (Kunshan) Co., Ltd. All Rights Reserved SU ICP:19068857